StoveTop FireStop Venthood Specifications
| StoveTop FireStop Venthood |
| Intended Use |
Small, residential stovetop frying pan fires (not deep-fat frying) |
| Activation Method |
Automatic when flame reaches device |
| Powder Dispersal Method |
Gravity (non-pressurized) |
| Primary Suppression Agent |
Non-toxic dry powder |
| Type of Vent Hood |
Traditional vent hoods |
| Required Vertical Clearance |
27-35" between the burner and the bottom of the surface where the magnet will attach |
| Required Horizontal Distance From Back Wall |
Not applicable (center one device over each side of the stovetop, between front and rear burners) |
| Weight |
Canisters each weigh 12 oz. but contain 9 oz. of powder
|
| Height |
3.5" (including magnet assembly) |
| Length |
3.4" (diameter) |
| Width |
3.4" (diameter) |
| Installation Method |
Industrial strength magnets (included) hold device to vent hood. Stainless steel fastening kit available upon request |
| Number of Devices Needed to Cover Four-Burner Stove |
Two (one pair) |
| Tests Performed |
Device and suppression agent tested by an independent nationally recognized testing laboratory (NRTL)
|
| Lifetime |
Replace after five years from date manufactured or upon activation |
.gif)
| Installation Instructions

To install Venthood, complete the following steps:
- Attach the ring to the magnet and to the can top.
- Center one can between the front and back burner on one side of the stove.
- Lift can straight up and attach.
- Repeat steps 1-3 for second can on the other side of the stove.
For detailed product instructions, click here .

|